Description
5.0kW Primo Gen24 Inverter, 208/240 VAC, 1-Phase, 200 – 480 VDC MPPT
The Fronius Primo Gen24 5.0kW Inverter is a cutting-edge single-phase solution engineered to meet the needs of today’s residential solar energy systems. Supporting both 208 and 240 VAC output, it delivers exceptional flexibility in system integration. Its built-in backup power outlet ensures that key appliances can remain powered during daylight hours—even when the grid is down and no battery is installed.
With a broad MPPT input range of 200 – 480 VDC, smart shading tolerance, and active cooling, the Primo Gen24 achieves high energy yields and long-term reliability. Designed and manufactured in Europe, this inverter blends robust performance with intelligent design, making it a top-tier choice for sustainable home energy.
Ideal for homeowners seeking resilience, energy independence, and long-term value, the 5.0kW Primo Gen24 Inverter is future-ready and compatible with additional smart energy solutions, including battery storage and home automation systems.
Key Benefits
-
-
Integrated Backup Power
Keep essential loads running during the day without the need for a battery. -
Wide MPPT Voltage Range (200–480 VDC)
Supports versatile array configurations for optimal design flexibility. -
Smart Shade Tolerance
Improves energy production in partial shading conditions. -
Active Cooling Technology
Enhances inverter performance and longevity in all climates. -
208/240 VAC Compatibility
Offers seamless integration with residential grid standards in North America. -
European Engineering Excellence
Built in Europe to exacting quality standards for maximum reliability. -
Scalable and Future-Ready
Easily integrates with future upgrades such as battery storage and smart grid features.
-
Specification
| Input Data | |
|---|---|
| Number of MPP trackers | 2 |
| PV input power | 5150 W |
| Feed-in start voltage (Udc start) | 80 V |
| Min. MPP voltage (U mpp min) | 230 V |
| Max. MPP voltage (U mpp max) | 480 V |
| Output Data PV Point | |
| Max. switchover time PV-Point | 17 s |
| Max. switchover time Full Backup | 17 s |
| General Data | |
| Mains Frequency | 60 1/s, 50 1/s |
| Width | 474 mm |
| Height | 516 mm |
| Depth | 165 mm |
| Weight | 15.08 kg |
| Weight incl. packaging | 18.7 kg |
| Protection class | 1 |
| Overvoltage category (DC / AC) | 2 / 4 |
| Inverter design | Transformerless |
| Cooling | Active Cooling Technology |
| Installation | Indoor and outdoor installation |
| Min. permissible ambient temperature | -40 °C |
| Max. permissible ambient temperature | 60 °C |
| DC PV connection technology | 2x DC+1, 2x DC+2 and 4x DC- spring-type terminals (AWG14-8) |
| DC battery connection technology | 1x DC+ and 1x DC- spring-type terminals (AWG 12-8) |
| AC connection technology | Spring-type terminals (AWG 14-8); Backup: AWG 16-8 |
| Back-up power functions | PV Point |
| Sound emissions | 42 dB(A) |
| Interference emission class | B |
| Protection Devices | |
| DC insulation measurement | Yes |
| Overload behaviour | Operating point shift, Power limitation |
| DC disconnector | Yes |
|
|
|